Sign In Join Help
 
Mediclean Technology Co.,LTD.

 
 
Recommended Results 
 
Cleanroom Microfiber Microdenier Swab MS714 

  Category : Textiles and clothing->Accessories->handbag accessories

     
Cleanroom Microfiber Microdenier Swab MS714
       

  Product Specification
 
  Model No:      MS714
  Country  CN
  Brand  Generic
  Payment Term  L/C,T/T,Paypal,Western Union

 

    Product Detail
  <p class="MsoNormal">
<b>Cleanroom Microfiber Microdenier Swab MS714</b>
</p>
<p class="MsoNormal">
<b><br />
</b>
</p>
<p class="MsoNormal">
<b>Description:</b>
</p>
<p class="MsoNormal">
Mediclean`s
Cleanroom Microfiber Tip Swabs MS714 feature
a large, rectangular head and a long handle. Microdenier
Cleanroom Swab MS714 is constructed from pure&nbsp; microfiber fabric material. Contec Microdenier Swabs over foam swab features
better capturing capacity of small particles. It is thermally bonded without
using adhesives. Laundered and assembled in class 10 cleanroom facility ensures
lowest level of contamination. Microfiber cleaning swab MS714 are widely used
for many rigorous industries such as pharmaceutical, microbiology, medical,etc.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<b>Compatible with:</b>
</p>
<p class="MsoNormal">
-
Texwipe TX714 cleanroom microfiber swab
</p>
<p class="MsoNormal">
Contact
us for more Texwipe compatible Cleanroom Microfiber Swabs
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<b>Specification:</b>
</p>
<p class="MsoNormal">
-
Model Number: MS714
</p>
<p class="MsoNormal">
-
Head Material: 100% Microfiber
</p>
<p class="MsoNormal">
-
Handle Material: 100% Polypropylene
</p>
<p class="MsoNormal">
-
Handle Colour: Green (White, Black, Blue is available upon request)
</p>
<p class="MsoNormal">
-
Standards Met: Class 10 ISO Class 4 Certified
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p>
<b>Dimension Chart:</b>
</p>
<p>
<b><img src="http://i.bosscdn.com/product/9a/8c/b5/1bd9531dac6318d355d432f3ff.png@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=23&p=5&t=80&text=bWVkaWNsZWFuLmJvc3Nnb28uY29t" title="MS714" alt="MS714" /><br />
</b>
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p class="MsoNormal">
<b>Features:</b>
</p>
<p class="MsoNormal">
-
Large, rectangular head and long handle
</p>
<p class="MsoNormal">
-
Lint-free microfiber fabric head
</p>
<p class="MsoNormal">
-
Durable and non-abrasive tip, good for high tolerance applications
</p>
<p class="MsoNormal">
-
Thermally bonded without adhesives or glues
</p>
<p class="MsoNormal">
-
Excellent compatibility with aggressive solvents
</p>
<p class="MsoNormal">
-
Microfiber feature better capturing capacity of micro particles
</p>
<p class="MsoNormal">
-
Low non-volatile residue contamination, low particulate
</p>
<p class="MsoNormal">
-
ESD handle is available as option
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<b>Applications:</b>
</p>
<p class="MsoNormal">
-
General purpose cleaning for board surface
</p>
<p class="MsoNormal">
-
Medical surface sampling, cleaning validation
</p>
<p class="MsoNormal">
-
Remove contamination from Disk Driver
</p>
<p class="MsoNormal">
-
Clean sensitive surface in optics, lens
</p>
<p class="MsoNormal">
-
Clean encoder magnetic head
</p>
<p class="MsoNormal">
-
Pick up micro particles, dust
</p>
<p class="MsoNormal">
-
Clean micro mechanical device
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<b>Packaging:</b>
</p>
<p class="MsoNormal">
100
swabs / bag
</p>
<p class="MsoNormal">
2
inner bags of 50 swabs
</p>
<p class="MsoNormal">
50
bags / case
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<b>Contamination Characteristics:</b>
</p>
<table class="MsoTableGrid" border="1" cellspacing="0" cellpadding="0" width="568" style="border:none;">
<tbody>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal" align="center" style="text-align:center;">
<b><span style="font-size:12.0pt;font-family:Arial ,sans-serif;">Property</span></b><span style="font-size:12.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal" align="center" style="text-align:center;">
<b><span style="font-size:12.0pt;font-family:Arial ,sans-serif;">Measurement</span></b><span style="font-size:12.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="251" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal" align="center" style="text-align:center;">
<b><span style="font-size:12.0pt;font-family:Arial ,sans-serif;">Test Method*</span></b><span style="font-size:12.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<b><span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Nonvolatile
Residue(NVR)</span></b><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:11.0pt;font-family:Arial ,sans-serif;">&nbsp;</span>
</p>
</td>
<td width="251" rowspan="2" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">TM10:
Procedure for Determining the Nonvolatile Residue (NVR) Extractable from
Swabs in a Given Solvent</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">IPA
Extractant</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">0.02
mg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<b><span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Ions</span></b><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:11.0pt;font-family:Arial ,sans-serif;">&nbsp;</span>
</p>
</td>
<td width="251" rowspan="10" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">TM12:
The Determination of Ions in Wipers and Other Materials by Capillary Ion
Analysis (CIA)</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Chloride</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Sulfate</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Nitrate</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Phosphate</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Fluoride</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Potassium</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Calcium</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Sodium</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
<tr>
<td width="189" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">Magnesium</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
<td width="128" style="border:solid windowtext 1.0pt;">
<p class="MsoNormal">
<span style="font-size:10.0pt;font-family:Arial ,sans-serif;">&lt;0.01
μg/swab</span><span style="font-size:11.0pt;font-family:Arial ,sans-serif;"></span>
</p>
</td>
</tr>
</tbody>
</table>
<p class="MsoNormal">
*:
Test procedures available upon request.
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p class="MsoNormal">
<b>ESD Characteristics:</b>
</p>
<p class="MsoNormal">
Handle
Resistivity: 10<sup>8</sup> – 10<sup>9</sup>&nbsp;
Ohms/Sq (Optional)
</p>
<p class="MsoNormal">
&nbsp;
</p>
<b>Picture:</b>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/20/2f/38/2a43fe541d6a1089967723c45d.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=23&p=5&t=80&text=bWVkaWNsZWFuLmJvc3Nnb28uY29t" title="Texwipe Compatible Cleanroom Microfiber Swab MS714 (2)" alt="Texwipe Compatible Cleanroom Microfiber Swab MS714 (2)" /><img src="http://i.bosscdn.com/product/34/ba/26/5f3923453ff196c8d32f34e58f.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=23&p=5&t=80&text=bWVkaWNsZWFuLmJvc3Nnb28uY29t" title="Texwipe Compatible Cleanroom Microfiber Swab MS714" alt="Texwipe Compatible Cleanroom Microfiber Swab MS714" />
</p>
<p>
<br />
</p>mediclean-tech.com

  More Products from this Supplier
 
Texwipe CleanFoam Compatible Swab FS746

Texwipe CleanFoam Compatible Swab FS746
Cleanroom Polyester Swab PS707 CleanTips

Cleanroom Polyester Swab PS707 CleanTips
Cleanroom Polyester Fabric Swab PS766

Cleanroom Polyester Fabric Swab PS766
Cleanroom Microfiber Swab MS761 Texwipe TX761 Compatible

Cleanroom Microfiber Swab MS761 Texwipe TX761 Compatible
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .